The calibration and setup processes for your probes are intended to be as straightforward as possible. You will instantly understand how to correctly configure your probes so that they will precisely match the conditions you will need to have for the greatest aquaculture environment! You will be able to handle it on your own after watching this brief and simple video.
Play video on YoutubeMeasuring water salinity is an important water quality parameter. Measurements obtained using the XB1-S probe mean that the optimum concentration of salt can be maintained in the water depending on the species of fish being farmed. The probe is also suitable for highly-polluted and highly-conductive water due to the four-electrode system.
Power supply | external source 18 ÷ 35V DC/ 30 mA |
Signal output | 4 ÷ 20 mA + MODBUS |
Temperature measuring range | -20 ÷ 120 °C |
Temperature measurement accuracy | ± 0,2 °C; ± 1dig. |
Conductivity measuring range | 0,00 ÷ 20,00 (30,00) μS/cm 0,0 ÷ 200,0 (300,0) μS/cm 0 ÷ 2000 (3000) μS/cm 0,00 ÷ 20,00 (30,00) mS/cm 0,0 ÷ 200,0 (300,0; 500,0) mS/cm |
Conductivity measuring accuracy | ± 0,5 %; ± 1dig. |
Temperature compensation | automatic -5 ÷ 110 °C |
Temperature compensation constant | 0 ÷ 3 % / K, according to EN 27 888 |
Reference temperature | 25 °C |
Concentration measurement range | 0 ÷ 300 g/l or 0 ÷ 30 % (up to 500 mS/cm), 5 ranges |
Salinity measurement range | 0 ÷ 70 g/l; 2 ranges |
Operating temperature range | 0 ÷ 50 °C |
Storage temperature range | -20 ÷ 70 °C |
Protection rating | IP 68 |
Dimensions (probe) | 270 x 36 mm |
Dimensions (box) | 320 x 200 x 75 mm |
Material | stainless steel 1,4404; PVC-U; PUR (cable) |
Maximum immersion depth | 30 m |